This article illustrates how the cable factor of deviated bundle tendons and accordingly the pressure between prestressing steel elements and ducts can be accurately determined. The knowledge of the maximum pressure between strand/wire to the duct of a bundle tendon is important both to estimate the danger of fatigue fracture of the prestressing steel due to fretting corrosion when using corrugated steel ducts and to estimate the imprints into polyethylene ducts of bondless tendons. Polyethylene ducts serve as corrosion protection sheathing for tendons. Especially for bondless tendons, it is necessary to limit the wear of ducts to ensure the corrosion protection of the steel, the durability of the tendon and the tensioned structure.

In the past, graphical methods were applied as well as costly and time-consuming simulations of the arrangement of strands or wires in a duct with the help of small-scale models. For configurations other than the ones tested or for a greater number of wires in a duct these results cannot be used. That is why the authors developed two numerical approaches of how to arrange strands/wires in a duct (Approach A: “Nonlinear Optimization”, Approach B: “M-PDS-algorithm”). After finding an optimal arrangement it is possible to determine the cable factors and thus the maximum pressure by the help of a two-dimensional truss calculation.

Finally, two approaches for estimating the maximum cable factor are presented. They reduce the calculation effort to different extents. The first approach is based on hydrostatic analogy. The second one is a simplified method that allows for a quick estimation with the help of the relevant parameters in a short formula. In contrast to the exact solutions, only the maximum value of the cable factors can be found, but not the pressures between strands/wires or the remaining pressures between strands/wires and duct, ‎[1].
Nevertheless, with the help of the tools presented in this article, the curvature design of deviated tendons can be reconsidered. In addition to this, they can contribute to a qualified assessment of the durability and efficiency of existing post-tensioning systems or to their development.